Technical Specifications - HPE ProLiant ML30 Generation9 Quickspecs

Table of Contents

Advertisement

QuickSpecs

Technical Specifications

System Unit
Tower Dimensions
(H x W x D)
Tower Weight
Input Requirements
BTU Rating
Power Supply Output
System Inlet Temperature
Relative Humidity
Altitude
Acoustic Noise
14.50 x 6.89 x 18.7 in (36.82 x 17.5 x 47.52 cm)
Minimum:
27.1lb(13.56kg)
Maximum:
30.8lb(15.4kg)
Range Line Voltage
100 to 120 VAC
Rated Input Current
2.5 to 6 Amps
Rated Input Frequency
Range Line Voltage
47 to 63 Hz
Rated Input Current
412W to 526W at 115 V AC input
412W to 523W at 230 V AC input
Maximum
460W - 1773 BTU / hr (at 120 VAC), 1715 (at
240 VAC)
Rated Steady-State
350 W (at 115 VAC)
Power
350 W (at 230 VAC)
Maximum Peak Power
350 W (at 115 VAC)
350 W (at 230 VAC)
Standard Operating
10° to 35°C (50° to 95°F) at sea level with an
Support
altitude derating of 1.0°C per every 304.8 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3048 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be limited
by the type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, noncondensing.
Operating
3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA 74)
and declared in accordance with ISO 9296 (ECMA 109).
Idle
LWAd
4.2 Bels (1P LFF Base)
3.7 Bels (1P LFF Performance)
LpAm
27 dBA (1P LFF Base)
23 dBA (1P LFF Performance)
HPE ProLiant ML30 Generation9 (Gen9)