Installing the two-bay SFF drive cage option
Installing the two-bay SFF drive cage option
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
Procedure
Procedure
1. If installed, remove the front bezel .
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Remove the access panel .
7. Remove the media bay blank:
a. Remove the screws securing the media bay blank.
Retain the screws for installing the optical drive cage.
b. Disengage the media bay blank.
c. Remove the media bay blank.
8. Install the drive cage.
Installing the two-bay SFF drive cage option