Fan option

Fan population

The number of fans installed in the server determines fan redundancy.
Configuration
1
4LFF
8SFF SAS or SATA
4LFF or 8SFF with a
GPU installed
1
8SFF NVMe
1
This configuration supports fan redundancy.

Fan mode behavior

In nonredundant fan mode, a fan failure or a missing fan causes:
The system Health LED to flash amber.
The operating system to orderly shutdown.
In redundant fan mode:
A fan rotor failure will switch the system to nonredundant fan mode.
This change is indicated by the Health LED flashing amber. The system continues to operate normally in this
mode.
A second fan rotor failure or a missing fan causes the operating system to orderly shutdown.

Installing a fan

This server supports redundant fans to provide sufficient airflow to the system if a fan rotor fails.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are
populated with either a component or a blank.
Procedure
1.
Power down the server.
2.
Remove all power:
Bay 1
Bay 2
Blank
Fan
1
Blank
Fan
Blank
Fan
Fan
Fan
Bay 3
Bay 4
Bay 5
Fan
Fan
Fan
Fan
Fan
Fan
Fan
Fan
Fan
Fan
Fan
Fan
Bay 6
Bay 7
Fan
Blank
Fan
Blank
Fan
Fan
Fan
Fan
Hardware options installation
79

Advertisement

Table of Contents
loading

Table of Contents