Advertisement

Parameters
● Parameter
Pr.
0 to 999
C2 (902)
C3 (902)
125 (903)
C4 (903)
C5 (904)
C6 (904)
126 (905)
C7 (905)
C12 (917)
C13 (917)
C14 (918)
C15 (918)
C16 (919)
C17 (919)
C18 (920)
C19 (920)
C8 (930)
C9 (930)
C10 (931)
C11 (931)
C38 (932)
C39 (932)
Tab. 5-273: Parameter
FR-F800
Register
Parameter name
41000 to
Refer to the parameter list (page 5-2)
41999
for the parameter names.
Terminal 2 frequency setting bias
41902
(frequency)
Terminal 2 frequency setting bias
42092
(analog value)
Terminal 2 frequency setting bias
43902
(terminal analog value)
Terminal 2 frequency setting gain
41903
(frequency)
Terminal 2 frequency setting gain
42093
(analog value)
Terminal 2 frequency setting gain
43903
(terminal analog value)
Terminal 4 frequency setting bias
41904
(frequency)
Terminal 4 frequency setting bias
42094
(analog value)
Terminal 4 frequency setting bias
43904
(terminal analog value)
Terminal 4 frequency setting gain
41905
(frequency)
Terminal 4 frequency setting gain
42095
(analog value)
Terminal 4 frequency setting gain
43905
(terminal analog value)
41917
Terminal 1 bias frequency (speed)
42107
Terminal 1 bias (speed)
Terminal 1 bias (speed)
43917
(terminal analog value)
41918
Terminal 1 gain frequency (speed)
42108
Terminal 1 gain (speed)
Terminal 1 gain (speed)
43918
(terminal analog value)
41919
Terminal 1 bias command (torque)
42109
Terminal 1 bias (torque)
Terminal 1 bias (torque)
43919
(terminal analog value)
41920
Terminal 1 gain command (torque)
42110
Terminal 1 gain (torque)
Terminal 1 gain (torque)
43920
(terminal analog value)
41930
Current output bias signal
42120
Current output bias current
41931
Current output gain signal
42121
Current output gain current
41932
Terminal 4 bias command (torque)
42122
Terminal 4 bias (torque)
Terminal 4 bias (torque)
43932
(terminal analog value)
(N) Operation via communication and its settings
Read/Write
Remarks
The parameter number + 41000
Read/write
is the register number.
Read/write
Read/write
Analog value (%) set to C3 (902) .
Analog value (%) of the voltage
Read
(current) applied to the terminal
2 .
Read/write
Read/write
Analog value (%) set to C4 (903) .
Analog value (%) of the voltage
Read
(current) applied to the terminal
2 .
Read/write
Read/write
Analog value (%) set to C6 (904) .
Analog value (%) of the current
Read
(voltage) applied to the terminal
4 .
Read/write
Read/write
Analog value (%) set to C7 (905) .
Analog value (%) of the current
Read
(voltage) applied to the terminal
4 .
Read/write
Analog value (%) set to C13
Read/write
(917)
Analog value (%) of the voltage
Read
applied to the terminal 1
Read/write
Read/write
Analog value (%) set to C15(918)
Analog value (%) of the voltage
Read
applied to the terminal 1
Read/write
Analog value (%) set to C17
Read/write
(919)
Analog value (%) of the voltage
Read
applied to the terminal 1
Read/write
Analog value (%) set to C19
Read/write
(920)
Analog value (%) of the voltage
Read
applied to the terminal 1
Read/write
Read/write
Analog value (%) set to C9 (930)
Read/write
Analog value (%) set to C11
Read/write
(931)
Read/write
Analog value (%) set to C39
Read/write
(932)
Analog value (%) of the current
Read
(voltage) applied to the terminal
4
5 - 517