Mitsubishi Electric FR-F820-00077 Instruction Manual page 186

Fr-f800 series
Hide thumbs Also See for FR-F820-00077:
Table of Contents

Advertisement

Parameter List
Pr.
Pr.
Name
group
655
M530
Analog remote output selection
656
M531
Analog remote output 1
657
M532
Analog remote output 2
658
M533
Analog remote output 3
659
M534
Analog remote output 4
Increased magnetic excitation
660
G130
deceleration operation selection
661
G131
Magnetic excitation increase rate
Increased magnetic excitation current
662
G132
level
Control circuit temperature signal
663
M060
output level
Regeneration avoidance frequency
665
G125
gain
668
A786
Power failure stop frequency gain
SF-PR slip amount adjustment
673
G060
operation selection
674
G061
SF-PR slip amount adjustment gain
684
C000
Tuning data unit switchover
686
E712
Maintenance timer 2
Maintenance timer 2 warning output
687
E713
set time
688
E714
Maintenance timer 3
Maintenance timer 3 warning output
689
E715
set time
Second free thermal reduction
692
H011
frequency 1
693
H012
Second free thermal reduction ratio 1
Second free thermal reduction
694
H013
frequency 2
695
H014
Second free thermal reduction ratio 2
Second free thermal reduction
696
H015
frequency 3
699
T740
Input terminal filter
702
C106
Maximum motor frequency
706
C130
Induced voltage constant (phi f )
707
C107
Motor inertia (integer)
711
C131
Motor Ld decay ratio
712
C132
Motor Lq decay ratio
Starting resistance tuning
717
C182
compensation
Starting magnetic pole position
721
C185
detection pulse width
724
C108
Motor inertia (exponent)
725
C133
Motor protection current level
Tab. 5-2:
Parameter overview (by number) (13)
5 - 14
Minimum
Setting range
setting
increments
0, 1, 10, 11
800 to 1200%
0.1%
800 to 1200%
0.1%
800 to 1200%
0.1%
800 to 1200%
0.1%
0, 1
0 to 40%, 9999
0.1%
0 to 300%
0.1%
0 to 100 °C
1 °C
0 to 200%
0.1%
0 to 200%
0.1%
2, 4, 6, 9999
0 to 500%
0.1%
0, 1
0 (1 to 9998)
0 to 9998, 9999
0 (1 to 9998)
0 to 9998, 9999
0 to 590 Hz, 9999
0.01 Hz
1 to 100%
1%
0 to 590 Hz, 9999
0.01 Hz
1 to 100%
1%
0 to 590 Hz, 9999
0.01 Hz
5 to 50 ms, 9999
1 ms
0 to 400 Hz, 9999
0.01 Hz
0 to 5000 mV/(rad/s),
0.1 mV/(rad/s)
9999
10 to 999, 9999
0 to 100%, 9999
0.1%
0 to 100%, 9999
0.1%
0 to 200%, 9999
0.1%
0 to 6000 μs,
10000 to 16000 μs,
1 μs
9999
0 to 7, 9999
100 to 500%, 9999
0.1%
Parameters
Initial value
Refer
to page
FM
CA
1
0
5-249
1000%
5-249
1000%
5-249
1000%
5-249
1000%
5-249
1
0
5-564
9999
5-564
100%
5-564
0 °C
5-254
100%
5-560
100%
5-432
1
9999
5-544
100%
5-544
5-303,
1
0
5-316
1
0
5-95
1
9999
5-95
1
0
5-95
1
9999
5-95
9999
5-150
100%
5-150
9999
5-150
100%
5-150
9999
5-150
9999
5-285
9999
5-316
9999
5-316
1
9999
5-316
9999
5-316
9999
5-316
9999
5-316
9999
5-316
1
9999
5-316
9999
5-316

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents