Parameter List
Pr.
Pr.
Name
group
Operation frequency during
779
N014
communication error
791
F070
Acceleration time in low-speed range
792
F071
Deceleration time in low-speed range
Pulse increment setting for output
799
M520
power
800
G200
Control method selection
820
G211
Speed control P gain 1
821
G212
Speed control integral time 1
822
T003
Speed setting filter 1
Torque control P gain 1 (current loop
824
G213
proportional gain)
Torque control integral time 1 (current
825
G214
loop integral time)
827
G216
Torque detection filter 1
828
G224
Parameter for manufacturer setting. Do not set.
830
G311
Speed control P gain 2
831
G312
Speed control integral time 2
832
T005
Speed setting filter 2
834
G313
Torque control P gain 2
835
G314
Torque control integral time 2
837
G316
Torque detection filter 2
849
T007
Analog input offset adjustment
858
T040
Terminal 4 function assignment
859
C126
Torque current/Rated PM motor current
Second motor torque current/Rated PM
860
C226
motor current
864
M470
Torque detection
866
M042
Torque monitoring reference
867
M321
AM output filter
868
T010
Terminal 1 function assignment
869
M334
Current output filter
870
M440
Speed detection hysteresis
H201
Input phase loss protection selection
872
874
H730
OLT level setting
Tab. 5-2:
Parameter overview (by number) (15)
5 - 16
Minimum
Setting range
setting
increments
0 to 590 Hz, 9999
0.01 Hz
0 to 3600 s, 9999
0 to 3600 s, 9999
0.1, 1, 10, 100, 1000 kWh
0.1 kWh
9, 20
0 to 1000%
0 to 20 s
0.001 s
0 to 5 s, 9999
0.001 s
0 to 500%
0 to 500 ms
0.1 ms
0 to 0.1 s
0.001 s
0 to 1000%, 9999
0 to 20 s, 9999
0.001 s
0 to 5 s, 9999
0.001 s
0 to 500%, 9999
0 to 500 ms, 9999
0.1 ms
0 to 0.1 s, 9999
0.001 s
0 to 200%
0, 4, 9999
0 to 500 A, 9999
0.01 A
0 to 3600 A, 9999
0.1 A
0 to 500 A, 9999
0.01 A
0 to 3600 A, 9999
0.1 A
0 to 400%
0 to 400%
0 to 5 s
0.01 s
0, 4, 9999
0 to 5 s
0.01 s
0 to 5 Hz
0.01 Hz
0, 1
0 to 400%
Initial value
Refer
to page
FM
CA
9999
5-459
0.1 s
9999
5-102
0.1 s
9999
5-102
1 kWh
5-253
1
20
5-41
1%
25%
5-55
0.333 s
5-55
9999
5-264
1%
50%
5-55
40 ms
5-55
0 s
5-59
1%
9999
5-55
9999
5-55
9999
5-264
1%
9999
5-55
9999
5-55
9999
5-59
0.1%
100%
5-264
5-180,
1
0
5-260
5-303,
9999
5-316
5-303,
9999
5-316
0.1%
150%
5-246
0.1%
150%
5-211
0.01 s
5-218
5-180,
1
0
5-260
0.02 s
5-218
0 Hz
5-240
1
0
5-163
0.1%
120%
110%
5-180
Parameters