YASKAWA E-7-Series SGD7S Product Manual page 521

Servo, analog voltage/pulse train references
Table of Contents

Advertisement

Parameter
Name
No.
Application Function
2
Selections 7
Analog Monitor 2 Signal Selection

n.
XX
Pn007
11 to 5F

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Application Function
2
Selections 8
Low Battery Voltage Alarm/Warning Selection

n.
X
Function Selection for Undervoltage
Pn008

n.
X
Warning Detection Selection

n.
X

n.X
Reserved parameter (Do not change.)
Setting
Setting
Range
Unit
0000 to
105F
Motor speed (1 V/1,000 min
00
Motor speed (1 V/1,000 mm/s)
Speed reference (1 V/1,000 min
01
Speed reference (1 V/1,000 mm/s)
Torque reference (1 V/100% rated torque)
02
Force reference (1 V/100% rated force)
03
Position deviation (0.05 V/reference unit)
Position amplifier deviation (after electronic gear) (0.05 V/encoder pulse unit)
04
Position amplifier deviation (after electronic gear) (0.05 V/linear encoder
pulse unit)
Position reference speed (1 V/1,000 min
05
Position reference speed (1 V/1,000 mm/s)
06
Reserved setting (Do not use.)
07
Load-motor position deviation (0.01 V/reference unit)
Positioning completion (positioning completed: 5 V, positioning not com-
08
pleted: 0 V)
Speed feedforward (1 V/1,000 min
09
Speed feedforward (1 V/1,000 mm/s)
Torque feedforward (1 V/100% rated torque)
0A
Force feedforward (1 V/100% rated force)
0B
Active gain (1st gain: 1 V, 2nd gain: 2 V)
Completion of position reference distribution (completed: 5 V, not com-
0C
pleted: 0 V)
0D
External encoder speed (1 V/1,000 min
0E
Position amplifier deviation (0.05 V/reference unit)
0F
Reserved setting (Do not use.)
10
Main circuit DC voltage
Reserved settings (Do not use.)
0000 to
7121
0
Output alarm (A.830) for low battery voltage.
1
Output warning (A.930) for low battery voltage.
0
Do not detect undervoltage.
1
Detect undervoltage warning and limit torque at host controller.
Detect undervoltage warning and limit torque with Pn424 and
2
Pn425 (i.e., only in SERVOPACK).
0
Detect warnings.
1
Do not detect warnings except for A.971.
14.1 List of Parameters
14.1.2 List of Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
Immedi-
0000
All
ately
-1
)
-1
)
-1
)
-1
)
-1
: value at the motor shaft)
After
0000
Rotary
restart
Classi-
Refer-
fication
ence
page
Setup
9-6
Setup
Reference
page 12-2
Reference
page 6-13
Reference
14
page 12-
45
14-7