Alarm Number:
Possible Cause
Alarm Name
The surrounding tem-
perature is too high.
An overload alarm
was reset by turning
OFF the power sup-
ply too many times.
A.7A1:
Internal Tempera-
There was an exces-
ture Error 1 (Con-
sive load or operation
trol Board
was performed that
Temperature
exceeded the regen-
Error)
erative processing
capacity.
The SERVOPACK
installation orientation
is not correct or there
is insufficient space
around the SERVO-
PACK.
A failure occurred in
the SERVOPACK.
The surrounding tem-
perature is too high.
An overload alarm
was reset by turning
OFF the power sup-
ply too many times.
A.7A2:
There was an exces-
Internal Tempera-
ture Error 2
sive load or operation
(Power Board
was performed that
Temperature
exceeded the regen-
Error)
erative processing
capacity.
The SERVOPACK
installation orientation
is not correct or there
is insufficient space
around the SERVO-
PACK.
A failure occurred in
the SERVOPACK.
A.7A3:
Internal Tempera-
ture Sensor Error
A failure occurred in
(An error
the SERVOPACK.
occurred in the
temperature sen-
sor circuit.)
Confirmation
Check the surrounding
temperature using a
Decrease the surround-
thermostat. Or, check
ing temperature by
the operating status
improving the SERVO-
with the SERVOPACK
PACK installation condi-
installation environment
tions.
monitor.
Check the alarm display
Change the method for
to see if there is an
resetting the alarm.
overload alarm.
Use the accumulated
load ratio to check the
load during operation,
Reconsider the load and
and use the regenera-
operating conditions.
tive load ratio to check
the regenerative pro-
cessing capacity.
Install the SERVOPACK
Check the SERVOPACK
according to specifica-
installation conditions.
tions.
The SERVOPACK may be
faulty. Replace the SER-
VOPACK.
Check the surrounding
temperature using a
Decrease the surround-
thermostat. Or, check
ing temperature by
the operating status
improving the SERVO-
with the SERVOPACK
PACK installation condi-
installation environment
tions.
monitor.
Check the alarm display
Change the method for
to see if there is an
resetting the alarm.
overload alarm.
Use the accumulated
load ratio to check the
load during operation,
Reconsider the load and
and use the regenera-
operating conditions.
tive load ratio to check
the regenerative pro-
cessing capacity.
Install the SERVOPACK
Check the SERVOPACK
according to specifica-
installation conditions.
tions.
The SERVOPACK may be
faulty. Replace the SER-
VOPACK.
The SERVOPACK may be
faulty. Replace the SER-
VOPACK.
12.2 Alarm Displays
12.2.2 Troubleshooting Alarms
Continued from previous page.
Reference
Correction
for Correc-
tion
page 3-3,
page 3-5
page 3-3,
page 3-5
12
12-23