14.1 List of Parameters
14.1.2 List of Parameters
Parameter
No.
Pn50A
14-22
Name
Input Signal Selections
2
1
Input Signal Allocation Mode
Use the sequence input signal terminals with the default alloca-
0
tions.

n.
X
1
Change the sequence input signal allocations.
2
Reserved setting (Do not use.)
/S-ON (Servo ON) Signal Allocation
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).

n.
X
7
The signal is always active.
8
The signal is always inactive.
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
/P-CON (Proportional Control) Signal Allocation

n.
X
The allocations are the same as the /S-ON (Servo ON) signal allo-
0 to F
cations.
P-OT (Forward Drive Prohibit) Signal Allocation
0
Enable forward drive when CN1-40 input signal is ON (closed).
1
Enable forward drive when CN1-41 input signal is ON (closed).
2
Enable forward drive when CN1-42 input signal is ON (closed).
3
Enable forward drive when CN1-43 input signal is ON (closed).
4
Enable forward drive when CN1-44 input signal is ON (closed).
5
Enable forward drive when CN1-45 input signal is ON (closed).
6
Enable forward drive when CN1-46 input signal is ON (closed).

n.X
7
Set the signal to always prohibit forward drive.
8
Set the signal to always enable forward drive.
9
Enable forward drive when CN1-40 input signal is OFF (open).
A
Enable forward drive when CN1-41 input signal is OFF (open).
B
Enable forward drive when CN1-42 input signal is OFF (open).
C
Enable forward drive when CN1-43 input signal is OFF (open).
D
Enable forward drive when CN1-44 input signal is OFF (open).
E
Enable forward drive when CN1-45 input signal is OFF (open).
F
Enable forward drive when CN1-46 input signal is OFF (open).
Setting
Setting
Default
Range
Unit
Setting
0000 to
2100
FFF2
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
page 6-4
Reference
page 5-17
Reference
page 8-65
Reference
page 5-31
Refer-
ence