Parameter
Name
No.
Input Signal Selections
2
2
N-OT (Reverse Drive Prohibit) Signal Allocation

n.
X
/ALM-RST (Alarm Reset) Signal Allocation
Pn50B

n.
X
/P-CL (Forward External Torque Limit Input) Signal Allocation

n.
X
0 to F
/N-CL (Reverse External Torque Limit Input) Signal Allocation

n.X
Setting
Setting
Range
Unit
0000 to
FFFF
0
Enable reverse drive when CN1-40 input signal is ON (closed).
1
Enable reverse drive when CN1-41 input signal is ON (closed).
2
Enable reverse drive when CN1-42 input signal is ON (closed).
3
Enable reverse drive when CN1-43 input signal is ON (closed).
4
Enable reverse drive when CN1-44 input signal is ON (closed).
5
Enable reverse drive when CN1-45 input signal is ON (closed).
6
Enable reverse drive when CN1-46 input signal is ON (closed).
7
Set the signal to always prohibit reverse drive.
8
Set the signal to always enable reverse drive.
9
Enable reverse drive when CN1-40 input signal is OFF (open).
A
Enable reverse drive when CN1-41 input signal is OFF (open).
B
Enable reverse drive when CN1-42 input signal is OFF (open).
C
Enable reverse drive when CN1-43 input signal is OFF (open).
D
Enable reverse drive when CN1-44 input signal is OFF (open).
E
Enable reverse drive when CN1-45 input signal is OFF (open).
F
Enable reverse drive when CN1-46 input signal is OFF (open).
Active on signal edge when CN1-40 input signal changes from
0
OFF (open) to ON (closed).
Active on signal edge when CN1-41 input signal changes from
1
OFF (open) to ON (closed).
Active on signal edge when CN1-42 input signal changes from
2
OFF (open) to ON (closed).
Active on signal edge when CN1-43 input signal changes from
3
OFF (open) to ON (closed).
Active on signal edge when CN1-44 input signal changes from
4
OFF (open) to ON (closed).
Active on signal edge when CN1-45 input signal changes from
5
OFF (open) to ON (closed).
Active on signal edge when CN1-46 input signal changes from
6
OFF (open) to ON (closed).
7
Reserved setting (Do not use.)
8
The signal is always inactive.
Active on signal edge when CN1-40 input signal changes from ON
9
(closed) to OFF (open).
Active on signal edge when CN1-41 input signal changes from ON
A
(closed) to OFF (open).
Active on signal edge when CN1-42 input signal changes from ON
B
(closed) to OFF (open).
Active on signal edge when CN1-43 input signal changes from ON
C
(closed) to OFF (open).
Active on signal edge when CN1-44 input signal changes from ON
D
(closed) to OFF (open).
Active on signal edge when CN1-45 input signal changes from ON
E
(closed) to OFF (open).
Active on signal edge when CN1-46 input signal changes from ON
F
(closed) to OFF (open).
The allocations are the same as the /S-ON (Servo ON) signal allocations. page 6-61
0 to F
The allocations are the same as the /S-ON (Servo ON) signal allocations. page 6-61
14.1 List of Parameters
14.1.2 List of Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
6543
All
restart
Classi-
Refer-
fication
ence
Setup
Reference
page 5-31
Reference
page 12-
40
Reference
14
Reference
14-23