YASKAWA E-7-Series SGD7S Product Manual page 535

Servo, analog voltage/pulse train references
Table of Contents

Advertisement

Parameter
Name
No.
Pn502
2
Rotation Detection Level 1 to 10,000
Speed Coincidence
Pn503
2
Detection Signal Output
Width
Brake Reference-Servo
Pn506
2
OFF Delay Time
Brake Reference Out-
Pn507
2
put Speed Level
Servo OFF-Brake Com-
Pn508
2
mand Waiting Time
Momentary Power Inter-
Pn509
2
ruption Hold Time
Setting
Setting
Default
Range
Unit
Setting
-1
20
1 min
-1
0 to 100
10
1 min
0 to 50
10 ms
0
-1
0 to 10,000
100
1 min
10 to 100
10 ms
50
20 to 50,000
1 ms
20
14.1 List of Parameters
14.1.2 List of Parameters
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
Immedi-
Rotary
Setup
ately
Immedi-
Rotary
Setup
ately
Immedi-
All
Setup
ately
Immedi-
Rotary
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Refer-
ence
page
6-10
page
6-25
page
5-36
page
5-36
page
5-36
page
6-12
14
14-21

Advertisement