Command And Drive Data Sets – Overview - Siemens CU230P-2 HVAC Parameter Manual

Sinamics g120 control units
Hide thumbs Also See for CU230P-2 HVAC:
Table of Contents

Advertisement

Parameters
Command and Drive Data Sets – Overview
p1140[0...n]
p1141[0...n]
p1142[0...n]
p1143[0...n]
p1144[0...n]
p1155[0...n]
p1160[0...n]
p1201[0...n]
p1230[0...n]
p1330[0...n]
p1455[0...n]
p1466[0...n]
p1476[0...n]
p1477[0...n]
p1478[0...n]
p1479[0...n]
p1486[0...n]
p1492[0...n]
p1500[0...n]
p1501[0...n]
p1503[0...n]
p1511[0...n]
p1512[0...n]
p1513[0...n]
p1522[0...n]
p1523[0...n]
p1528[0...n]
p1529[0...n]
p1552[0...n]
p1554[0...n]
p1571[0...n]
p2103[0...n]
p2104[0...n]
p2105[0...n]
p2106[0...n]
p2107[0...n]
p2108[0...n]
p2112[0...n]
p2116[0...n]
p2117[0...n]
p2144[0...n]
p2148[0...n]
p2151[0...n]
p2200[0...n]
p2220[0...n]
p2221[0...n]
p2222[0...n]
p2223[0...n]
p2235[0...n]
p2236[0...n]
p2253[0...n]
p2254[0...n]
p2264[0...n]
1-410
BI: Ramp-function generator enable / RFG enable
BI: Continue ramp-function generator / Continue RFG
BI: Speed setpoint enable / n_set enable
BI: Ramp-function generator, accept setting value / Accept RFG set val
CI: Ramp-function generator setting value / RFG setting value
CI: Speed controller speed setpoint 1 / n_ctrl n_set 1
CI: Speed controller speed setpoint 2 / n_ctrl n_set 2
BI: Flying restart enable signal source / Fly_res enab S_src
BI: DC brake activation / DC brake active
CI: V/f control independent voltage setpoint / Vf V_set independ.
CI: Speed controller P gain adaptation signal / n_ctrl Adpt_sig Kp
CI: Speed controller P-gain scaling / n_ctrl Kp scal
BI: Speed controller hold integrator / n_ctrl integ stop
BI: Speed controller set integrator value / n_ctrl integ set
CI: Speed controller integrator setting value / n_ctr integ_setVal
CI: Speed controller integrator setting value scaling / n_ctrl I_val scal
CI: Droop compensation torque / Droop M_comp
BI: Droop feedback enable / Droop enable
Torque setpoint selection / M_set sel
BI: Change over between closed-loop speed/torque control / Changeov n/M_ctrl
CI: Torque setpoint / M_set
CI: Supplementary torque 1 / M_suppl 1
CI: Supplementary torque 1 scaling / M_suppl 1 scal
CI: Supplementary torque 2 / M_suppl 2
CI: Torque limit upper / M_max upper
CI: Torque limit lower / M_max lower
CI: Torque limit upper scaling / M_max upper scal
CI: Torque limit lower scaling / M_max lower scal
CI: Torque limit upper scaling without offset / M_max up w/o offs
CI: Torque limit lower scaling without offset / M_max low w/o offs
CI: Supplementary flux setpoint / Suppl flux setp
BI: 1. Acknowledge faults / 1. Acknowledge
BI: 2. Acknowledge faults / 2. Acknowledge
BI: 3. Acknowledge faults / 3. Acknowledge
BI: External fault 1 / External fault 1
BI: External fault 2 / External fault 2
BI: External fault 3 / External fault 3
BI: External alarm 1 / External alarm 1
BI: External alarm 2 / External alarm 2
BI: External alarm 3 / External alarm 3
BI: Motor stall monitoring enable (negated) / Mot stall enab neg
BI: Ramp-function generator active / HLG active
CI: Speed setpoint for messages/signals / n_set for msg
BI: Technology controller enable / Tec_ctrl enable
BI: Technology controller fixed value selection bit 0 / Tec_ctrl sel bit 0
BI: Technology controller fixed value selection bit 1 / Tec_ctrl sel bit 1
BI: Technology controller fixed value selection bit 2 / Tec_ctrl sel bit 2
BI: Technology controller fixed value selection bit 3 / Tec_ctrl sel bit 3
BI: Technology controller motorized potentiometer raise setpoint / Tec_ctrl mop raise
BI: Technology controller motorized potentiometer lower setpoint / Tec_ctrl mop lower
CI: Technology controller setpoint 1 / Tec_ctrl setp 1
CI: Technology controller setpoint 2 / Tec_ctrl setp 2
CI: Technology controller actual value / Tec_ctrl act val
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009