p1781[0...n]
Motor model Rs adaptation integral time / MotMod Rs Tn
Access level: 4
Can be changed: U, T
Min
10 [ms]
Description:
Sets the integral time for the Rs adaptation of the motor model for an induction motor (ASM).
r1782[0...n]
Motor model Rs adaptation corrective value / MotMod Rs corr
Access level: 4
Unit: [Ohm]
Description:
Displays the corrective value for the Rs adaptation of the motor model for an induction motor (ASM).
Dependency:
Refer to: p0826, p1780
Note:
The display of the inactive data sets is only updated when changing over the data set.
p1783[0...n]
Motor model Rs adaptation Kp / MotMod Rs Kp
Access level: 4
Can be changed: U, T
Min
0.000
Description:
Sets the proportional gain for the Rs adaptation of the motor model for an induction motor (ASM).
p1785[0...n]
Motor model Lh adaptation Kp / MotMod Lh Kp
Access level: 4
Can be changed: U, T
Min
0.000
Description:
Sets the proportional gain for the Lh adaptation of the motor model for an induction motor (ASM).
p1786[0...n]
Motor model Lh adaptation integral time / MotMod Lh Tn
Access level: 4
Can be changed: U, T
Min
10 [ms]
Description:
Sets the integral time for the Lh adaptation of the motor model for an induction motor (ASM).
r1787[0...n]
Motor model Lh adaptation corrective value / MotMod Lh corr
Access level: 4
Unit: [mH]
Description:
Displays the corrective value for the Lh adaptation of the motor model for an induction motor (ASM).
Dependency:
Refer to: p0826, p1780
Note:
The adaptation result is reset if the magnetizing inductance of the induction motor is changed (p0360, r0382). This
also happens when changing over the data set if a different motor is not being used (p0826).
The display of the inactive data sets is only updated when changing over the data set.
r1789
Motor model Rs adaptation switch-in frequency / MotMod Rs f_on
Access level: 4
Unit: [Hz]
Description:
Displays the power-on stator frequency for the Rs adaptation for the induction motor (ASM).
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Calculated: p0340 = 1,3,4
Scaling: -
Max
10000 [ms]
Calculated: -
Scaling: -
Calculated: p0340 = 1,3,4
Scaling: -
Max
1.000
Calculated: p0340 = 1,3,4
Scaling: -
Max
1.000
Calculated: p0340 = 1,3,4
Scaling: -
Max
10000 [ms]
Calculated: -
Scaling: -
Calculated: -
Scaling: -
Parameters
List of Parameters
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
100 [ms]
Data type: FloatingPoint32
Data set: DDS, p0180
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.100
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.100
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
100 [ms]
Data type: FloatingPoint32
Data set: DDS, p0180
Data type: FloatingPoint32
Data set: -
1-209