List of Parameters
p20267
LVM 0 interval average value M / LVM 0 avg value M
Access level: 3
Can be changed: T
Min
-340.28235E36
Description:
Setting parameter for the interval average M of instance LVM 0 of the double-sided limiter.
p20268
LVM 0 interval limit L / LVM 0 limit L
Access level: 3
Can be changed: T
Min
-340.28235E36
Description:
Setting parameter for the interval limit L of instance LVM 0 of the double-sided limiter.
p20269
LVM 0 hyst HY / LVM 0 hyst HY
Access level: 3
Can be changed: T
Min
-340.28235E36
Description:
Setting parameter for hysteresis HY of instance LVM 0 of the double-sided limiter.
r20270
BO: LVM 0 input quantity above interval QU / LVM 0 X above QU
Access level: 3
Unit: -
Description:
Display parameter of instance LVM 0 of the double-sided limiter that input quantity X was at least once X > M + L
and X is >= M + L - HY.
r20271
BO: LVM 0 input quantity within interval QM / LVM 0 X within QM
Access level: 3
Unit: -
Description:
Display parameter of instance LVM 0 of the double-sided limiter that the input quantity X lies within the interval.
r20272
BO: LVM 0 input quantity below interval QL / LVM 0 X below QL
Access level: 3
Unit: -
Description:
Display parameter of instance LVM 0 of the double-sided limiter that input quantity X was at least once X < M - L
and X is <= M - L + HY.
p20273
LVM 0 run-time group / LVM 0 RTG
Access level: 3
Can be changed: T
Min
5
Description:
Setting parameter for the run-time group in which instance LVM 0 of the double-sided limiter is to be called.
Value:
5:
6:
9999: Do not calculate
1-388
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Max
340.28235E36
Calculated: -
Scaling: -
Max
340.28235E36
Calculated: -
Scaling: -
Max
340.28235E36
Calculated: -
Scaling: -
Calculated: -
Scaling: -
Calculated: -
Scaling: -
Calculated: -
Scaling: -
Max
9999
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Data type: FloatingPoint32
Data set: -
Factory setting
0.0000
Data type: FloatingPoint32
Data set: -
Factory setting
0.0000
Data type: FloatingPoint32
Data set: -
Factory setting
0.0000
Data type: Unsigned32
Data set: -
Data type: Unsigned32
Data set: -
Data type: Unsigned32
Data set: -
Data type: Integer16
Data set: -
Factory setting
9999