Parameters
List of Parameters
p20328
RSR 2 run sequence / RSR 2 RunSeq
Access level: 3
Can be changed: T
Min
0
Description:
Setting parameter for the run sequence of instance RSR 2 within the run-time group set in p20327.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20329[0...3]
BI: DFR 2 inputs / DFR 2 inputs
Access level: 3
Can be changed: T
Min
-
Description:
Sets the signal source for trigger input I, D input D, set input S, and reset input R of instance DFR 2 of the D flipflop.
Index:
[0] = Trigger input I
[1] = D input D
[2] = Set S
[3] = Reset R
r20330
BO: DFR 2 output Q / DFR 2 output Q
Access level: 3
Unit: -
Description:
Display parameter for output Q of instance DFR 2 of the D flipflop.
r20331
BO: DFR 2 inverted output QN / DFR 2 inv outp QN
Access level: 3
Unit: -
Description:
Display parameter for the inverted output QN of instance DFR 2 of the D flipflop.
p20332
DFR 2 run-time group / DFR 2 RTG
Access level: 3
Can be changed: T
Min
1
Description:
Setting parameter for the run-time group in which instance DFR 2 of the D flipflop is to be called.
Value:
1:
2:
3:
4:
5:
6:
9999: Do not calculate
p20333
DFR 2 run sequence / DFR 2 RunSeq
Access level: 3
Can be changed: T
Min
0
Description:
Setting parameter for the run-time group of instance DFR 2 within the run-time group set in p20332.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
1-396
Run-time group 1
Run-time group 2
Run-time group 3
Run-time group 4
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Max
7999
Calculated: -
Scaling: -
Max
-
Calculated: -
Scaling: -
Calculated: -
Scaling: -
Calculated: -
Scaling: -
Max
9999
Calculated: -
Scaling: -
Max
32000
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Data type: Unsigned16
Data set: -
Factory setting
850
Data type: U32 / Binary
Data set: -
Factory setting
0
Data type: Unsigned32
Data set: -
Data type: Unsigned32
Data set: -
Data type: Integer16
Data set: -
Factory setting
9999
Data type: Unsigned16
Data set: -
Factory setting
870