Siemens CU230P-2 HVAC Parameter Manual page 391

Sinamics g120 control units
Hide thumbs Also See for CU230P-2 HVAC:
Table of Contents

Advertisement

p20287
DIF 0 run-time group / DIF 0 RTG
Access level: 3
Can be changed: T
Min
5
Description:
Setting parameter for the run-time group in which instance DIF 0 of the differentiating element is to be called.
Value:
5:
6:
9999: Do not calculate
p20288
DIF 0 run sequence / DIF 0 RunSeq
Access level: 3
Can be changed: T
Min
0
Description:
Setting parameter for the run sequence of instance DIF 0 within the run-time group set in p20287.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20300
BI: NOT 4 input I / NOT 4 input I
Access level: 3
Can be changed: T
Min
-
Description:
Sets the signal source of input quantity I of instance NOT 4 of the inverter.
r20301
BO: NOT 4 inverted output / NOT 4 inv output
Access level: 3
Unit: -
Description:
Display parameter for the inverted output of instance NOT 4 of the inverter.
p20302
NOT 4 run-time group / NOT 4 RTG
Access level: 3
Can be changed: T
Min
1
Description:
Setting parameter for the run-time group in which the instance NOT 4 of the inverter is to be called.
Value:
1:
2:
3:
4:
5:
6:
9999: Do not calculate
p20303
NOT 4 run sequence / NOT 4 RunSeq
Access level: 3
Can be changed: T
Min
0
Description:
Setting parameter for the run sequence of instance NOT 4 within the run-time group set in p20302.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Run-time group 5
Run-time group 6
Run-time group 1
Run-time group 2
Run-time group 3
Run-time group 4
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Max
9999
Calculated: -
Scaling: -
Max
32000
Calculated: -
Scaling: -
Max
-
Calculated: -
Scaling: -
Calculated: -
Scaling: -
Max
9999
Calculated: -
Scaling: -
Max
32000
Parameters
List of Parameters
Data type: Integer16
Data set: -
Factory setting
9999
Data type: Unsigned16
Data set: -
Factory setting
750
Data type: U32 / Binary
Data set: -
Factory setting
0
Data type: Unsigned32
Data set: -
Data type: Integer16
Data set: -
Factory setting
9999
Data type: Unsigned16
Data set: -
Factory setting
770
1-391