Siemens CU230P-2 HVAC Parameter Manual page 369

Sinamics g120 control units
Hide thumbs Also See for CU230P-2 HVAC:
Table of Contents

Advertisement

p20151
PCL 0 run-time group / PCL 0 RTG
Access level: 3
Can be changed: T
Min
5
Description:
Setting parameter for the run-time group in which the instance PCL 0 of the pulse shortener is to be called.
Value:
5:
6:
9999: Do not calculate
p20152
PCL 0 run sequence / PCL 0 RunSeq
Access level: 3
Can be changed: T
Min
0
Description:
Setting parameter for the run sequence of instance PCL 0 within the run-time group set in p20151.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20153
BI: PCL 1 input pulse I / PCL 1 inp_pulse I
Access level: 3
Can be changed: T
Min
-
Description:
Sets the signal source for the input pulse I of instance PCL 1 of the pulse shortener.
p20154
PCL 1 pulse duration in ms / PCL 1 pulse_dur ms
Access level: 3
Can be changed: T
Min
0.00
Description:
Setting parameter for pulse duration T in milliseconds of instance PCL 1 of the pulse shortener.
r20155
BO: PCL 1 output Q / PCL 1 output Q
Access level: 3
Unit: -
Description:
Display parameter for output pulse Q of instance PCL 1 of the pulse shortener.
p20156
PCL 1 run-time group / PCL 1 RTG
Access level: 3
Can be changed: T
Min
5
Description:
Setting parameter for the run-time group in which the instance PCL 1 of the pulse shortener is to be called.
Value:
5:
6:
9999: Do not calculate
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Run-time group 5
Run-time group 6
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Max
9999
Calculated: -
Scaling: -
Max
32000
Calculated: -
Scaling: -
Max
-
Calculated: -
Scaling: -
Max
60000.00
Calculated: -
Scaling: -
Calculated: -
Scaling: -
Max
9999
Parameters
List of Parameters
Data type: Integer16
Data set: -
Factory setting
9999
Data type: Unsigned16
Data set: -
Factory setting
400
Data type: U32 / Binary
Data set: -
Factory setting
0
Data type: FloatingPoint32
Data set: -
Factory setting
0.00
Data type: Unsigned32
Data set: -
Data type: Integer16
Data set: -
Factory setting
9999
1-369