Siemens CU230P-2 HVAC Parameter Manual page 370

Sinamics g120 control units
Hide thumbs Also See for CU230P-2 HVAC:
Table of Contents

Advertisement

Parameters
List of Parameters
p20157
PCL 1 run sequence / PCL 1 RunSeq
Access level: 3
Can be changed: T
Min
0
Description:
Setting parameter for the run sequence of instance PCL 1 within the run-time group set in p20156.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20158
BI: PDE 0 input pulse I / PDE 0 inp_pulse I
Access level: 3
Can be changed: T
Min
-
Description:
Sets the signal source for the input pulse I of instance PDE 0 of the closing delay device.
p20159
PDE 0 pulse delay time in ms / PDE 0 t_del ms
Access level: 3
Can be changed: T
Min
0.00
Description:
Setting parameter for pulse delay time T in milliseconds of instance PDE 0 of the closing delay device.
r20160
BO: PDE 0 output Q / PDE 0 output Q
Access level: 3
Unit: -
Description:
Display parameter for output pulse Q of instance PDE 0 of the closing delay device.
p20161
PDE 0 run-time group / PDE 0 RTG
Access level: 3
Can be changed: T
Min
5
Description:
Setting parameter for the run-time group in which instance PDE 0 of the closing delay device is to be called.
Value:
5:
6:
9999: Do not calculate
p20162
PDE 0 run sequence / PDE 0 RunSeq
Access level: 3
Can be changed: T
Min
0
Description:
Setting parameter for the run sequence of instance PDE 0 within the run-time group set in p20161.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20163
BI: PDE 1 input pulse I / PDE 1 inp_pulse I
Access level: 3
Can be changed: T
Min
-
Description:
Sets the signal source for the input pulse I of instance PDE 1 of the closing delay device.
1-370
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Max
32000
Calculated: -
Scaling: -
Max
-
Calculated: -
Scaling: -
Max
60000.00
Calculated: -
Scaling: -
Calculated: -
Scaling: -
Max
9999
Calculated: -
Scaling: -
Max
32000
Calculated: -
Scaling: -
Max
-
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Data type: Unsigned16
Data set: -
Factory setting
410
Data type: U32 / Binary
Data set: -
Factory setting
0
Data type: FloatingPoint32
Data set: -
Factory setting
0.00
Data type: Unsigned32
Data set: -
Data type: Integer16
Data set: -
Factory setting
9999
Data type: Unsigned16
Data set: -
Factory setting
430
Data type: U32 / Binary
Data set: -
Factory setting
0
© Siemens AG 2009 All Rights Reserved

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu230p-2 dpCu230p-2 can

Table of Contents