p1466[0...n]
CI: Speed controller P-gain scaling / n_ctrl Kp scal
Access level: 4
Can be changed: T
Min
-
Description:
Sets the signal source for the scaling of the P gain of the speed controller. This also makes the effective P gain
(including adaptations) scalable.
r1468
CO: Speed controller P-gain effective / n_ctrl Kp eff
Access level: 4
Unit: -
Description:
Displays the effective P gain of the speed controller.
r1469
Speed controller integral time effective / n_ctrl Tn eff
Access level: 4
Unit: [ms]
Description:
Displays the effective integral time of the speed controller.
p1470[0...n]
Speed controller encoderless operation P-gain / n_ctrl SLVC Kp
Access level: 2
Can be changed: U, T
Min
0.000
Description:
Sets the P gain for encoderless operation for the speed controller.
Note:
The product p0341 * p0342 is taken into account when automatically calculating the speed controller (p0340 = 1, 3,
4).
p1472[0...n]
Speed controller encoderless operation integral time / n_ctrl SLVC Tn
Access level: 2
Can be changed: U, T
Min
0.0 [ms]
Description:
Set the integral time for encoderless operation for the speed controller.
p1476[0...n]
BI: Speed controller hold integrator / n_ctrl integ stop
Access level: 4
Can be changed: T
Min
-
Description:
Sets the signal source to hold the integrator for the speed controller.
p1477[0...n]
BI: Speed controller set integrator value / n_ctrl integ set
Access level: 3
Can be changed: T
Min
-
Description:
Sets the signal source to set the integrator setting value (p1478).
Dependency:
Refer to: p1478, p1479
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
1-184
Calculated: -
Scaling: PERCENT
Max
-
Calculated: -
Scaling: -
Calculated: -
Scaling: -
Calculated: p0340 = 1,3,4
Scaling: -
Max
999999.000
Calculated: p0340 = 1,3,4
Scaling: -
Max
100000.0 [ms]
Calculated: -
Scaling: -
Max
-
Calculated: -
Scaling: -
Max
-
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Data type: U32 / FloatingPoint32
Data set: CDS, p0170
Factory setting
1
Data type: FloatingPoint32
Data set: -
Data type: FloatingPoint32
Data set: -
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.300
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
20.0 [ms]
Data type: U32 / Binary
Data set: CDS, p0170
Factory setting
0
Data type: U32 / Binary
Data set: CDS, p0170
Factory setting
0