p20113
MUL 0 run sequence / MUL 0 RunSeq
Access level: 3
Can be changed: T
Min
0
Description:
Setting parameter for the run sequence of instance MUL 0 within the run-time group set in p20112.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20114[0...3]
CI: MUL 1 inputs / MUL 1 inputs
Access level: 3
Can be changed: T
Min
-
Description:
Sets the signal source of the factors X0, X1, X2, X3 of instance MUL 1 of the multiplier.
Index:
[0] = Factor X0
[1] = Factor X1
[2] = Factor X2
[3] = Factor X3
r20115
CO: MUL 1 product Y / MUL 1 product Y
Access level: 3
Unit: -
Description:
Display parameter for the product Y = X0 * X1 * X2 * X3 of instance MUL 1 of the multiplier.
p20116
MUL 1 run-time group / MUL 1 RTG
Access level: 3
Can be changed: T
Min
5
Description:
Setting parameter for the run-time group in which instance MUL 1 of the multiplier is to be called.
Value:
5:
6:
9999: Do not calculate
p20117
MUL 1 run sequence / MUL 1 RunSeq
Access level: 3
Can be changed: T
Min
0
Description:
Setting parameter for the run sequence of instance MUL 1 within the run-time group set in p20116.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20118[0...1]
CI: DIV 0 inputs / DIV 0 inputs
Access level: 3
Can be changed: T
Min
-
Description:
Sets the signal source of dividend X1 and divisor X2 of instance DIV 0 of the divider.
Index:
[0] = Dividend X1
[1] = Divisor X2
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Max
32000
Calculated: -
Scaling: PERCENT
Max
-
Calculated: -
Scaling: PERCENT
Calculated: -
Scaling: -
Max
9999
Calculated: -
Scaling: -
Max
32000
Calculated: -
Scaling: PERCENT
Max
-
Parameters
List of Parameters
Data type: Unsigned16
Data set: -
Factory setting
270
Data type: U32 / FloatingPoint32
Data set: -
Factory setting
0
Data type: FloatingPoint32
Data set: -
Data type: Integer16
Data set: -
Factory setting
9999
Data type: Unsigned16
Data set: -
Factory setting
280
Data type: U32 / FloatingPoint32
Data set: -
Factory setting
0
1-363