Siemens CU230P-2 HVAC Parameter Manual page 387

Sinamics g120 control units
Hide thumbs Also See for CU230P-2 HVAC:
Table of Contents

Advertisement

p20260
BI: INT 0 accept setting value S / INT 0 acc set val
Access level: 3
Can be changed: T
Min
-
Description:
Sets the signal source for the "accept setting value" signal of instant INT 0 of the integrator.
r20261
CO: INT 0 output Y / INT 0 output Y
Access level: 3
Unit: -
Description:
Display parameter for output quantity Y of instance INT 0 of the integrator.
If LL>= LU, then the output quantity Y = LU.
r20262
BO: INT 0 integrator at the upper limit QU / INT 0 QU
Access level: 3
Unit: -
Description:
Display parameter for the signal QU that output quantity Y of instance INT 0 of the integrator has reached the upper
limit value LU.
r20263
BO: INT 0 integrator at the lower limit QL / INT 0 QL
Access level: 3
Unit: -
Description:
Display parameter for the signal QL that output quantity Y of instance INT 0 of the integrator has reached the lower
limit value LL.
p20264
INT 0 run-time group / INT 0 RTG
Access level: 3
Can be changed: T
Min
5
Description:
Setting parameter for the run-time group in which instance INT 0 of the integrator is to be called.
Value:
5:
6:
9999: Do not calculate
p20265
INT 0 run sequence / INT 0 RunSeq
Access level: 3
Can be changed: T
Min
0
Description:
Setting parameter for the run sequence of instance INT 0 within the run-time group set in p20264.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20266
CI: LVM 0 input X / LVM 0 input X
Access level: 3
Can be changed: T
Min
-
Description:
Sets the signal source of input quantity X of instance LVM 0 of the double-sided limiter.
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Max
-
Calculated: -
Scaling: PERCENT
Calculated: -
Scaling: -
Calculated: -
Scaling: -
Calculated: -
Scaling: -
Max
9999
Calculated: -
Scaling: -
Max
32000
Calculated: -
Scaling: PERCENT
Max
-
Parameters
List of Parameters
Data type: U32 / Binary
Data set: -
Factory setting
0
Data type: FloatingPoint32
Data set: -
Data type: Unsigned32
Data set: -
Data type: Unsigned32
Data set: -
Data type: Integer16
Data set: -
Factory setting
9999
Data type: Unsigned16
Data set: -
Factory setting
700
Data type: U32 / FloatingPoint32
Data set: -
Factory setting
0
1-387