Procedure for Alarm Actions Configuration

3DB 23063 ADAA - Rev 004 July 2007
1. To configure alarm mapping, select
to Figure 11-1 on page 11-2.
2. To add a destination Node or Terminal in the Alarm Action Destinations
panel, click
. Up to 30 destinations can be added.
Add
3. In Destination Address, enter the IP address for the destination Node/
Terminal. This updates the IP address for the new entry in the Alarm Actions
Destination panel.
• If the destination Node/Terminal is the local Node/Terminal (output port is
on the same Node/Terminal as the input/alarm source), use the same IP
address as the local Node/Terminal, or use the standard IP loopback address:
127.0.0.1.
• Where a different set of alarms or inputs is to be sent to a same destination
(same IP address), but to a different AUX plug-in, or different output port,
use a separate Alarm Action Destination entry.
4. In Slot, select the slot location of the target AUX plug-in for the destination
Node. This updates the entry in the Alarm Actions Destination panel.
Where the destination is a 9500 MXC Terminal, the Terminal resolves slot
location; any valid slot number (1 to 9) entered in the originating 9500 MXC is
default connected to the AUX I/O function in the destination Terminal.
For standardization purposes, it is recommended Slot 1 is used to identify an
AUX destination in a Terminal.
5. In Output, select the target output port on the destination AUX plug-in. This
updates the entry in the Alarm Actions Destination panel.
6. In the Triggers selection panel click to select the required input and/or alarm
events.
• The alarm tree can be expanded (toggle-tail down) to show available alarms
for all installed plug-ins.
• Inputs are found on the AUX plug-in(s).
• Circular tags adjacent to each alarm and input selection box indicates current
status. A red dot in the circle indicates active.
• Multiple alarms and/or inputs can be selected. The number (quantity)
selected updates the entry in the Alarm Actions Destination panel.
7. To commit the configuration, click
9500 MXC User Manual
>
Configuration
Alarm Actions
.
Send
. Refer
Vol. IV-11-3