Ncc/Idu Alarms - Alcatel-Lucent 9500 MXC User Manual

Microwave cross connect
Table of Contents

Advertisement

NCC/IDU Alarms

FPGA Software Load Failure (All)
Probable Cause
Recommended Actions
Additional Information
Vol. VI-B-2
• Several alarms are common to a number of the modules. Within Appendix B
they are only shown once (in order of first appearance), and their heading is
suffixed by '(All)'. These alarms are:
• FPGA Software Load Failure
• EEPROM Failure
• Configuration Not Supported
• Software/Hardware Incompatible.
This alarm information should be used in conjunction with 9500 MXC
Troubleshooting, which for electronic copy includes links to this appendix under
its CT Alarms section.
To view alarms and informational events from within the Helpset, use the links
from the Troubleshooting Guide. Go to CT Alarms or to Informational Events in
9500 MXC Troubleshooting, Volume V, Chapter 2.
The software loading of the Field Programmable Gate Array has failed. This is a
critical alarm.
Equipment or process malfunction.
1. If the alarm is raised on initial power-on, retry (reboot); power off, pause,
power on.
2. If the alarm is raised after a new SW load, reload the previous SW version and
re-check the alarm. If cleared, retry the SW load.
3. If the alarm is raised after a capacity or backplane reconfiguration, revert to
the previous settings. If the alarm has cleared, retry the new configuration.
4. If the alarm is permanent, replace the plug-in/IDU.
FPGA loading occurs:
Alcatel-Lucent

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents