DAC GE Performance

DAC GE Performance Screen Navigation
3DB 23063 ADAA - Rev 004 July 2007
Statistic
Switch Stats Out 1023
Octets
Switch Stats Out Max
Octets
Switch Stats Collisions
The DAC GE performance screen is similar in appearance and operation to the
DAC ES screen. See DAC ES and IDU ES Performance on page 15-33.
Select the DAC GE from the Module menu.
On opening, the Performance Statistics lines are empty. To enable, click the Start
All button. Data aggregates from this point forward for as long as CT is logged
on, or until the Stop All or Clear All buttons are selected.
Error events are shown with red text.
Viewing other CT screens does not affect the aggregation of performance
statistics.
The Stop All button terminates the data aggregation, but leaves for viewing the
data collected / displayed to that point.
The Clear All button clears all data.
If the Node is powered off, reset or the DAC GE withdrawn during data capture,
a warning is displayed advising that collected data has been interrupted.
Table 15-4 lists the available port and channel based RMON data.
Description of DAC GE RMON Performance Statistics
Table 15-4.
Name
UcastPkts
BroadcastPkts
MulticastPkts
Description
The total number of frames transmitted with a length of
between 512 and 1023 octets inclusive, including those with
errors.
Total frames transmitted with a length of between 1024 and
1522 octets inclusive, including those with errors.
Total number of collisions during the frame transmission.
Description
Number of Unicast frames received.
Number of broadcast frames received.
(InBroadcasts)
Number of multicast frames received.
(InMulticasts)