circuit has been configured but not classified as commissioned.
Go to the CT circuits screen and tick the commissioned/uncommissioned box to
show commissioned.
When a trib is commissioned, it and its associated circuit should be named. Trib
naming is done in the Plug-ins screen; circuit naming in the Circuits screen.
AIS received on tributary. This is a warning alarm.
AIS has been detected on a trib input due to an alarm condition within the
connected equipment, or upstream from the directly connected equipment.
Investigate the AIS source, first in the directly connected equipment, and then in
its upstream connections.
AUX alarm input is active, where 'n' can be 1 to 6 for a Node, or 1 to 2 for a
Terminal. This is a warning alarm.
AUX alarm input is active.
Investigate the cause of the activating event.
This alarm draws attention to a changed, active state on a configured AUX alarm