Link Down
Probable Cause
Recommended Actions
Link Degraded
Probable Cause
Recommended Actions
DAC 155oM Alarms
PMC TEMAP Access Failure
Probable Cause
Recommended Actions
3DB 23063 ADAA - Rev 004 July 2007
A channel link in the DAC GE is down. This is a major alarm.
Traffic received on the alarmed channel is errored. The errors may be caused by
equipment/circuit malfunction or radio path degradation.
Check for other link alarms (RAC, DAC 155oM), which may indicate a failed
link, a degraded path or an equipment malafunction.
Replace the DAC GE.
A channel link in the DAC GE is degraded in capacity. This is a warning alarm.
Traffic received on the alarmed channel is degraded in capacity. The errors may
be caused by equipment/circuit malfunction or radio path degradation.
Check for other link alarms (RAC, DAC 155oM), which may indicate a degraded
path or an equipment malafunction.
Replace the DAC GE.
No communications with the mapper IC. This is a critical alarm.
Equipment malfunction.
Withdraw the DAC 155oM, pause, then reinsert.
Replace the DAC 155oM.
9500 MXC User Manual
Vol. VI-B-51