Vol. VI-A-12
• Sensitive adds a 10
will occur on occurrence of a standard wrap event and/or a 10
Similarly an unwrap will not occur until after completion of an error-free
period that is clear of any standard or 10
• The Error-free Timer sets the period of error-free operation needed prior to
initiation of an unwrap. (When a wrap has occurred the timer counts down
towards an unwrap as soon as all wrap conditions are cleared. The count
begins anew should a wrap condition re-occur during the countdown).
Default is 5 minutes (recommended).
• The Delay Ring Unwrap option allows setting of a time of day when an
unwrap will occur providing all wrap conditions have been cleared for a
period not less than that set in the Error-free Timer.
- With this option selected the Wrap and Unwrap criteria default to
Standard.
- The Delay Ring Unwrap has a 1-hour window. If the conditions which
caused the wrap are not cleared by the Error-free Timer during this
window, then Delay Ring Unwrap resets for the same time the
following day.
• The System/Controls screen provides a countdown timer to indicate the time
to go before the ring will unwrap. Applies to both the Error-free Timer and
Delay Ring Unwrap Timer. (Counts down to zero).
5. To reverse the East and West roles, click on the 'Swap East with West' tab.
6. Click Send to save the configuration.
-6
BER event to the wrap and/or unwrap criteria. A wrap
-6
-6
BER event.
BER events.