Alcatel-Lucent 9500 MXC User Manual page 761

Microwave cross connect
Table of Contents

Advertisement

Traffic Path Down
Probable Cause
Recommended Actions
Protection Cable Unplugged
Probable Cause
Recommended Actions
DAC Alarms
LIU Failure
Probable Cause
3DB 23063 ADAA - Rev 004 July 2007
The radio path is down. True for non-protected and for protected/diversity
configurations. This is a critical alarm.
Path loss or equipment malfunction.
1. Check for path loss.
• Traffic will be affected in both directions.
• A complete path loss will almost invariably be preceded by a low RSL and
BER alarms; check CT History and Event Browser screens and associated
event help.
2. Check equipment.
• An equipment related path loss should be signalled by alarms from the
ODU, RAC, or NCC.
• Such alarms may be at the local or remote end and may be one-way or
both-way traffic affecting.
Unable to detect the protection cable. This is a warning alarm.
Cable not present/disconnected.
Check/install the protection cable.
No communications with the LIU (line interface unit). This is a critical alarm.
Equipment malfunction.
9500 MXC User Manual