Settings, Protection and ATPC

13
If just one of the co-channel links is 1+1 protected, a failure of XPIC cross-connect between the 1+0
RAC 40 and its 1+1 XPIC partner may cause both V and H receive streams to error as the discrimination
provided under XPIC would be lost. An unlikely double-failure event would be needed to cause the same
error if both co-channel links are 1+1 protected.
14
Optimum XPIC interference cancellation performance requires equal, or near equal V and H receive
signal levels.
3DB 23063 ADAA - Rev 004 July 2007
• Each RAC 40 in a co-channel XPIC pairing must be configured for the same
frequency, capacity and modulation.
• A special Tx mute function applies if one of the receive RACs fails, the RAC is
withdrawn, or the XPIC cables are removed or incorrectly connected. Refer to
Remote Tx Mute.
• Co-channel links may also be hot-standby or diversity protected using two
RAC 40s per vertical and horizontal feed. The protection partners must be
installed in the same INUe and slot-located according to INU/INUe RAC
protection rules.
• Where co-channel links are to be 1+1 protected, both must be 1+1
13
protected
.
• The RAC 40 assigned to each polarization is 1+1 protected by adding a RAC
40 protection partner in the CT Protection screen.
• For hot-standby or frequency diversity protection using a single dual
polarized antenna at each end, remote-mounted equal-loss couplers
be used to mount the ODUs.
• Similarly, for space diversity operation all four antennas must be of the same
size (have the same gain).
• The protected V and H links operate as two independent links - the standard
protection switch criteria for protected links apply. Refer to Hot-standby and
Diversity Switching Criteria on page 3-93.
• Similarly, the Remote Tx mute functions apply where both RACs of a
protected pair fail, are withdrawn, or have their XPIC cables removed or
incorrectly connected. Refer to Remote Tx Mute.
• RAC 40s can be operated in single channel/non-XPIC mode to provide an
upgrade path to co-channel operation without hardware changes.
• ATPC must be OFF on both co-channel links. (Receive signal level
measurements are affected by the interference caused on one link by the other,
which results in abnormal ATPC action).
9500 MXC User Manual
14
must
Vol. II-3-105