3DB 23063 ADAA - Rev 004 July 2007
• Towards the NOC a single default gateway is entered on each Node/Terminal
instead of static routes.
• Away from the NOC static entries are required in the normal way - each Node/
Terminal must have an entry for all other Nodes/Terminals that are on its away
side only.
• No static routes are required from Nodes/Terminals to address NOC host
devices (PCs, Server), meaning NMS PCs (9500 MXC CT) can be added/
removed from the NOC LAN without affecting network visibility.
• At the NOC, each of the LAN hosts (PCs, Server) are also configured with a
default gateway in their TCP/IP properties. (Just as an Ethernet connected 9500
MXC CT PC is configured to use its directly-connected Node/Terminal as its
default gateway). Entry of static routes to Nodes/Terminals is not required.
For information on static routing, default gateway application and example
networks, refer to Appendix D.
Static Routing Screen
Figure 10-2.
1
2
3
4
5
6
Item
Description
1
Static Routing selected.
2
User-defined fields for destination, mask, interface, and next hop.
3
Shows a new (still to be defined) route line added.
9500 MXC User Manual
Vol. IV-10-7