Alcatel-Lucent 9500 MXC User Manual page 671

Microwave cross connect
Table of Contents

Advertisement

IDU LED Alarm Triggers
Table 2-3.
LED
Indication
IDU Status
Orange
flashing:
Red:
ODU Status
Orange
flashing:
Red:
3DB 23063 ADAA - Rev 004 July 2007
Possible Causes
Either:
• Configuration corrupt
• Configuration not supported
• Software loading
• Diagnostic mode selected
Either:
• IDU component failure
• Power supply failure
• Modulator not locked
• Demodulator not locked
• IDU cable demodulator not
locked
• Aux channel clock failure
Either:
• Diagnostic mode selected/active
• Software loading (new 9500
MXC software is being loaded)
Either:
• ODU component failure
• ODU power supply failure or
current/voltages outside limits
• ODU communications failure
• Tx synthesizer not locked
• Transceiver Tx failure
• Tx power failure
• Tx If synthesizer not locked
• Tuner not locked
• ODU cable demodulator not
locked
9500 MXC User Manual
Recommended Action
Where the cause is not obvious, use CT to see
detail at a lower alarm level.
Repair action is required. The failure may or
may not be causing traffic disruption. Use
CT to see detail at a lower alarm level.
Where cause is not obvious, use CT to see
detail at a lower alarm level.
Repair action is required. The failure may or
may not be causing traffic disruption. Use
CT to see detail at a lower alarm level.
Vol. V-2-15