2.1.4 Stacking configuration

To manage more directions the "Stacking configuration" can be realized by installing up to 3 MSS, inter-
connected through the Ethernet ports in the Core-E module. In the example of Figure 10 are shown the
interconnected MSS.
For the Stacking configuration it is recommended to enable the Static Lag Criteria.
Also with the Core protection max. 3 MSS can be interconnected as shown in Figure 11. For the syn-
chronization connection refer to par. 2.8.25.
To implement this configuration the LOS alarm on the Ethernet ports must be enabled as switching cri-
terion of the Core protection. To enable this functionality the "Ethernet LOS Criteria" feature has to be
enabled (refer to Menu System Setting in par. 3.4.4).
User Manual
Product information and planning

Figure 10. Stacking configuration with 3 MSS