Chapter 4. Outdoor Units

ODU Construction and Mounting

3DB 23063 ADAA - Rev 004 July 2007
This chapter introduces:
• ODU Construction and Mounting on page 4-1
• ODU Data on page 4-2
Housings are similar for ODU 300ep and ODU 300hp. Construction comprises:
• Cast aluminium base (alloy 380)
• Pressed aluminium cover (sheet grade alloy 1050).
• Base and cover passivated and then polyester powder coated
• Compression seal for base-cover weatherproofing
• Carry-handle
9500 MXC ODU 300ep Housing
Figure 4-1.
The ODUs include a waveguide antenna port, Type-N female connector for the
ODU cable, a BNC female connector (with captive protection cap) for RSSI
access, and a grounding stud.