Procedure for DAC 16x, DAC 4x or IDU Tributary Configuration
3DB 23063 ADAA - Rev 004 July 2007
Item
Description
3
Tributary Lines user-defined entries:
• Commissioned. Configured tribs should be ticked as commissioned. When
commissioned, LOS alarms are raised if LOS is detected, and AIS alarms are
raised if AIS is detected.
• Name. Each trib can be individually named/identified.
• Impedance. Select 75 ohm unbalanced or 120 ohm balanced.
4
Icon indicates an active line-facing loopback.
5
Icon indicates an active radio-facing loopback.
6
Icon indicates a trib LOS alarm - no input signal.
7
Icons indicate trib in/out OK.
8
Fill Selection sets all selected (high-lighted) tribs to the same setting as the
top-most selected trib.
Figure 6-5 shows a typical DAC Tributary Lines screen for a DAC 16x (16xE1
or 16xDS1), which for the shown E1 setting provides a view/change capability
by line for commissioned/uncommissioned, tributary name, tributary impedance/
encoding and tributary status.
To configure E1/DS1 tributaries:
1. From the Plug-ins screen, select the required module.
9500 MXC Node
Click on the required DAC to bring up
its Tributary Lines screen.
2. Select the required Tributary Type, E1 or DS1.
3. Check/set Required Bus Type.When changing a tributary type, the backplane
bus must be set to match the selection. Reset using the Bus Configuration
selector in the Circuits screen; click Required Bus Type to go directly to the
Circuits screen. If not set correctly, the Required Bus Type displays a warning
icon.