Agilent Technologies 8163A Programming Manual page 96

Lightwave multimeter; lightwave measurement system; lightwave multichannel system
Hide thumbs Also See for 8163A:
Table of Contents

Advertisement

Measurement Operations & Settings
example:
affects:
dual sensors:
command:
syntax:
description:
parameters:
Measurement Running
Measurement Stopped
N O T E
N O T E
N O T E
N O T E
response:
example:
affects:
dual sensors:
96
sens1:func:par:minm?
All power meters and return loss modules
Can only be sent to master channel, slave channel parameters are identical.
Setting parameters for the stability function sets some parameters,
N O T E
including hidden parameters, for the logging and MinMax functions and
vice versa. You must use the
:SENSe[n][:CHANnel[m]]:FUNCtion:PARameter:STABility command to set
parameters before you start a stability function using the
:SENSe[n][:CHANnel[m]]:FUNCtion:STATe command.
:SENSe[n][:CHANnel[m]]:FUNCtion:PARameter:STABility
:SENSe[n][:CHANnel[m]]:FUNCtion:PARameter:STABility<wsp>
<total time>[NS|US|MS|S],<period time>[NS|US|MS|S],<averaging time>[NS|US|MS|S]
Sets the total time, period time, and averaging time for the stability data acquisition function.
Total time:
The total time from the start of stability mode until it is completed.
Period time:
A new measurement is started after the completion of every period time.
Averaging time:
A measurement is averaged over the averaging time.
1
The total time should be longer than the period time.
The period time should be longer than the averaging time.
The number of data points is equal to the total time divided by the period time.
Total time, period time, and averaging time are time values in seconds.
If you specify no units in your command, seconds are used as the default.
See ":SENSe[n][:CHANnel[m]]:FUNCtion:STATe" on page 100 for information on starting/stop-
ping a data acquisition function.
See ":SENSe[n][:CHANnel[m]]:FUNCtion:RESult?" on page 97 for information on accessing the
results of a data acquisition function.
See "Triggering and Power Measurements" on page 171 for information on how triggering af-
fects data acquisition functions.
none
sens1:func:par:stab 1s,0.1s,0.1s
All power meters and return loss modules
Can only be sent to master channel, slave channel is also affected.
Measurement Functions – The SENSe Subsystem
WIND,+10<END>
Averaging Time
Period Time
2
3
Agilent 8163A/B, 8164A/B & 8166A/B Mainframes, Fifth Edition
4
5
t