Cisco Catalyst 4500 Series Configuration Manual page 570

Ios software configuration guide isco ios xe 3.9.0e and ios 15.2(5)ex
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

options timeout (netflow-lite exporter submode)
options timeout (netflow-lite exporter submode)
NetFlow-lite is supported only on the Catalyst 4948E and Catalyst 4948E-F Ethernet switches.
Note
To specify an options timeout for the NetFlow-lite collector, use the options timeout command. To
delete the value, use the no form of this command.
Syntax Description
sampler-table
interface-table
seconds
Command Default
1800 seconds
Command Modes
netflow-lite exporter submode
Command History
Release
15.0(2)SG
Usage Guidelines
Default timeout value is 1800 seconds or 30 minutes. The timeout value configured really depends on
the collector and how often it needs the templates to be refreshed.
Examples
The following example shows how to specify an options timeout for the NetFlow-lite collector:
Switch# config terminal
Switch(config)# netflow-lite exporter exporter1
Switch(config-netflow-lite-exporter)# destination 5.5.5.6
Switch(config-netflow-lite-exporter)# source 5.5.5.5
Switch(config-netflow-lite-exporter)# transport udp 8188
Switch(config-netflow-lite-exporter)# ttl 128
Switch(config-netflow-lite-exporter)# cos 7
Switch(config-netflow-lite-exporter)# dscp 32
Switch(config-netflow-lite-exporter)# template data timeout 1
Switch(config-netflow-lite-exporter)# options sampler-table timeout 1
Switch(config-netflow-lite-exporter)# options interface-table timeout 1
Switch(config-netflow-lite-exporter)# export-protocol netflow-v9
Switch(config-netflow-lite-exporter)# exit
Switch(config)#
Catalyst 4500 Series Switch Cisco IOS Command Reference—Release XE 3.9.xE and 15.2(5)Ex
2-530
options {sampler-table | interface-table} timeout seconds
no options {sampler-table | interface-table} timeout second
Specifies timeout value for export of sampler configuration.
Specifies timeout value for export of snmp ifIndex mapping.
Specifies a n options timeout for the NetFlow-lite collector.
Modification
This command was introduced on the Catalyst 4500 series switch.
Chapter 2