Cisco Catalyst 4500 Series Configuration Manual page 622

Ios software configuration guide isco ios xe 3.9.0e and ios 15.2(5)ex
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

power redundancy-mode
power redundancy-mode
To configure the power settings for the chassis, use the power redundancy-mode command. To return
to the default setting, use the default form of this command.
Syntax Description
redundant
combined
Command Default
Redundant power management mode
Command Modes
Global configuration mode
Command History
Release
12.1(12c)EW
Usage Guidelines
The two power supplies must be the same type and wattage.
If you have power supplies with different types or wattages installed in your switch, the switch will not
Caution
recognize one of the power supplies. A switch set to redundant mode will not have power redundancy.
A switch set to combined mode will use only one power supply.
In redundant mode, the power from a single power supply must provide enough power to support the
switch configuration.
Table 2-12
supply.
Catalyst 4500 Series Switch Cisco IOS Command Reference—Release XE 3.9.xE and 15.2(5)Ex
2-582
power redundancy-mode {redundant | combined}
default power redundancy-mode
Configures the switch to redundant power management mode.
Configures the switch to combined power management mode.
Modification
This command was introduced on the Catalyst 4500 series switch.
lists the maximum available power for chassis and Power over Ethernet for each power