Symmetricom TimeProvider 5000 User Manual page 265

Ieee 1588 grand master clock / ntp server
Hide thumbs Also See for TimeProvider 5000:
Table of Contents

Advertisement

To Delete the non-fixed VLAN configuration for VLAN ID=75 on port 1 of IOC1 
tp5000> set vlan-config delete ioc1-1 non-fixed vlan-id 75
Example 5:
To Enable the fixed VLAN configuration for Index 5 on port 1 of IOC1 
tp5000> set vlan-config state ioc1-1 index 5 enable
Example 5a:
To Enable the non-fixed VLAN configuration for VLAN ID=75on port 1 of IOC1 
tp5000> set vlan-config state ioc1-1 non-fixed vlan-id 99
Example 6:
To Enable the VLAN for expansion shelf 1 (id=exp0) 
tp5000> set vlan-mode exp0 enable
Example 7:
To configure a VLAN on port 3 of expansion shelf 5 (id: exp4) with VLAN ID = 25,
Priority=0, layer 2 
tp5000> set vlan-config expansion exp4 port 3 vlan-id 25
priority
Level :
Admin only
098-00028-000 Revision F – May, 2012
enable
0 layer2
Chapter 3
TimeProvider 5000 CLI Command Set
TimeProvider 5000 User's Guide 265

Advertisement

Table of Contents
loading

Table of Contents