Symmetricom TimeProvider 5000 User Manual page 412

Ieee 1588 grand master clock / ntp server
Hide thumbs Also See for TimeProvider 5000:
Table of Contents

Advertisement

Appendix A System Messages
System Notification Messages
Table A-1. System Notification Messages (Continued)
Comp
Description
GNSS/GPS
antenna
open-circuit
Table A-2
(See
for
Secondary Index Info)
Battery(-48V)-A
failure
EXPx
x = 09
Battery(-48V)-B
failure
EXPx
x = 09
FPGA access
failure
IOC1
IOC2
EXPx
x = 09
Flash partition
failure
IOC1
IOC2
EXPx
Table A-2
(See
for
x = 09
Secondary Index Info)
Phase-lock-loop
(PLL) unlock error
410 TimeProvider 5000 User's Guide
Event
MsgLevel
ID
ID
IMC
13
Minor
IMC
14
Major
IMC
15
Major
IMC
16
Critical
IMC
17
Critical
IMC
18
Critical
Trans-
MsgText
itory
No
GNSS/GPS antenna
open-circuit
GNSS/GPS antenna
open- circuit cleared
No
Battery (-48V) -A
failure
Battery (-48V) -A
failure cleared
No
Battery (-48V) -B
failure
Battery (-48V) -B
failure cleared
No
FPGA access failure
FPGA access failure
cleared
No
Flash partition
failure
Flash partition
failure cleared
No
PLL unlock error
PLL unlock error
cleared
098-00028-000 Revision F – May, 2012
Corrective Action
Check all cable and
antenna
connections, check
voltage suppressor
None required
Troubleshoot the
-48V power supply.
Check voltage
supply to A side of
shelf
None required
Troubleshoot the
-48V power supply.
Check voltage
supply to B side of
shelf
None required
Hardware fault
-Replace module
None required
Hardware fault
-Replace module
None required
Reboot System - If
alarm remains,
replace module
None required

Advertisement