Timeprovider 5000, Tp E10, And Tp E30 Mechanical Specifications; Timeprovider 5000, Tp E10, And Tp E30 Environmental Specifications - Symmetricom TimeProvider 5000 User Manual

Ieee 1588 grand master clock / ntp server
Hide thumbs Also See for TimeProvider 5000:
Table of Contents

Advertisement

Appendix B Specifications and Factory Defaults
Specifications
Specifications
This section provides the specifications for the TimeProvider 5000 components and
input and output signals. This section also provides the specifications for the
TimeProvider E10 and TimeProvider E30 expansion shelves.and their output
signals.
Mechanical
Table B-1. TimeProvider 5000, TP E10, and TP E30 Mechanical Specifications
Parameter
Mounting
Rack Mounting Position
Width
Height
Depth
Weight
Environmental
Table B-2. TimeProvider 5000, TP E10, and TP E30 Environmental Specifications
Parameter
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
430 TimeProvider 5000 User's Guide
Description
19 in. Rack
For front mounting location unit protrudes 0.65 in /
1.651 cm
Figure 2-5
Figure 2-6
See
,
drawings with detailed chassis dimensions.
17.24 in. / 438 mm
1.73 in. / 44 mm
17.12 in. / 435 mm  TP 5000
9.37 in. / 236 mm  TP E10 & TP E30
9.6 lb. / 4.4 kg fully loaded  TP 5000
8.4 lb. / 3.8 kg  TP E10 & TP E30
Description
-5 to 45C, 23 to 113 F  TP 5000
-5 to 55C, 23 to 131 F  TP E10 & TP E30
–25 to 70  C, –13 to 158 F
90% to 100% RH, maximum, w/condensation
5% to 100% RH w/condensation
Figure 2-7
, and
for
098-00028-000 Revision F – May, 2012