Chapter 4 Provisioning
Provisioning Expansion Shelf E1 / 1PPS+TOD Outputs
CCS Frame Type
To provision E1 output Port 4 on expansion shelf 1 (ID=exp0) with a frametype of
CCS, CRC enabled, SSM enabled, SSM-bit of 6, and to enable the port:
1. Login at the Admin or Config-user level.
2. Type
set output-exp e1 frametype exp0 port 4 ccs
3. Type
set output-exp e1 crc exp0 port 4 enable
4. Type
set output-exp e1 ssm exp0 port 4 enable
5. Type
set output-exp e1 ssm-bit exp0 port 4 6
6. Type
set output-exp e1 state exp0 port 4 enable
CAS Frame Type
To provision E1 output Port 4 on expansion shelf 1 (ID=exp0) with a frametype of
CAS, CRC enabled, SSM-bit of 8, and to enable the port:
1. Login at the Admin or Config-user level.
2. Type
set output-exp e1 frametype exp0 port 4 cas
3. Type
set output-exp e1 crc exp0 port 4 enable
4. Type
set output-exp e1 ssm exp0 port 4 enable
5. Type
set output-exp e1 ssm-bit exp0 port 4 8
6. Type
set output-exp e1 state exp0 port 4 enable
Output Generation Behavior
Output generation behavior can be configured independently for individual ports or
the same behavior can be configured for all E1 ports on the specified expansion
shelf.
1. Login at the Admin or Config-user level.
2. Type
set output-exp e1 warm-up exp0 all squelch
3. Type
set output-exp e1 free-run exp0 all ais
338 TimeProvider 5000 User's Guide
and press Enter.
and press Enter.
and press Enter.
and press Enter.
and press Enter.
and press Enter.
and press Enter.
and press Enter.
and press Enter.
and press Enter.
and press Enter.
and press Enter.
098-00028-000 Revision F – May, 2012