Chapter 4 Provisioning
Saving and Restoring Provisioning Data

Restoring Provisioning Data

Example 1
To change the current configuration to factory default while preserving user and IP
information, enter the following:
1. Type
set configuration default
Example 2
To change the current configuration to the factory default, enter the following:
1. Type
set configuration factory
Notes: Setting the configuration to default will not overwrite the
user login information or the IP address of MGMT port of IMC. Setting
the configuration to factory will overwrite the user login information
and return the IP address of MGMT port of IMC to the factory set
address.
Example 3
To restore the expansion shelf with ID=3 with its stored configuration from the IMC
card, enter the following:
1. Type
set configuration restore exp3-from-imc
Example 4
To restore the configuration data with a file name of tp5k_ioc_backup.txt for the
active IOC from a remote site, which is an SFTP server with the IP address of
172.16.33.33, id: tp5000, password: backup:
1. Type
set configuration restore remote ioc
c:\sftp\tp5k_ioc_backup.txt sftp:172.16.33.33 tp5000
Enter.
2. The system will prompt for the password. Enter the password and press Enter.
Note:
appropriate for the FTP/SFTP server and the operating system
on which it is running. This includes whether the entire path
should be specified and whether "/" or "\" characters should be
used
352 TimeProvider 5000 User's Guide
For remote storage, path names should be specified as
.
and press Enter.
and press Enter.
and press Enter.