– The interval is 2
To provision the interval between delay response messages for PTP Unicast
static:
set ptp unicast static delay-int {ioc1-1 | ioc1-2}
index [1 - 10] <delay-int-value>
– The interval is 2
Expansion Shelf Attributes (Multicast):
To provision the state of the PTP outputs for the PTP/Synce expansion shelf:
set ptp state exp[0-9] [port[1-16] | all] [enable | disable]
To provision the PTP timescale for the PTP/Synce expansion shelf:
set ptp timescale exp[0-9] [auto | arb | ptp]
To provision the PTP clock to two-step or one-step mode for the PTP/Synce
expansion shelf:
set ptp two-step exp[0-9] [enable | disable]
To provision the PTP alternate-master for the PTP/Synce expansion shelf:
set ptp alternate-master exp[0-9] [enable | disable]
To provision the Priority 1 value for the PTP/Synce expansion shelf:
set ptp priority1 exp[0-9] <priority1-value>
To provision the Priority 2 value for the PTP/Synce expansion shelf:
set ptp priority2 exp[0-9] <priority2-value>
To provision domain for the PTP/Synce expansion shelf:
set ptp domain exp[0-9] <domain-value>
To provision the dither for the for the PTP/Synce expansion shelf:
set ptp dither exp[0-9] [enable | disable]
To provision the clock ID for the PTP/Synce expansion shelf:
set ptp clockid exp[0-9] <clockid-value>
Note: : If the Alternate Master mode is set to Enable, the alternate
master flag will be set in the PTP messages. If the alternate master
flag is set, the TP5000 will not run the Best Master Clock (BMC)
algorithm and will stay in master mode.
098-00028-000 Revision F – May, 2012
z
seconds, where z= <announce-int-value>.
z
seconds, where z= <delay-limit-value>.
Chapter 3
TimeProvider 5000 CLI Command Set
TimeProvider 5000 User's Guide 209