Selecting Mib Versions - Symmetricom TimeProvider 5000 User Manual

Ieee 1588 grand master clock / ntp server
Hide thumbs Also See for TimeProvider 5000:
Table of Contents

Advertisement

Chapter 4 Provisioning
Provisioning for SNMP

Selecting MIB Versions

Use the "set snmp trap-mib" and "set snmp sys-obj-mib" commands to select the
MIB version to be used for traps and system, respectively.
Example:
To select the v2.0 trap MIB and v2.0 sys-obj MIB.:
1. Type
set snmp trap-mib 2.0
2. Type
set snmp sys-obj-mib 2.0
Adding or Deleting a Manager IP Address
Use the "set snmp add manager" command to add a manager IP address. Use the
"set snmp delete manager" command to delete a manager IP address. The TP5000
will support a maximum of 3 manager IP addresses.
Example:
To add the SNMP manager IP address
0x12345678901234567890
1. Type
set snmp add manager 192.100.100.100 engineid
0x12345678901234567890
Provisioning to Generate v2 Traps
Use the "set snmp trapversion" command to provision the trap version to v2.
The default trap version is v2. By default, therefore, the TP5000 will generate v2
traps if the SNMP option is activated.
Example:
1. Type
set snmp trapversion 2
Provisioning to Generate v3 Traps
Use the "set snmp trapversion" command to provision the trap version to v3.
Example
1. Type
set snmp trapversion 3
356 TimeProvider 5000 User's Guide
then press Enter.
then press Enter.
192.100.100.100,
:
then press Enter.
then press Enter.
then press Enter.
using an engineID
098-00028-000 Revision F – May, 2012