Set Synce Command Hierarchy; Setting The System Date And Time - Symmetricom TimeProvider 5000 User Manual

Ieee 1588 grand master clock / ntp server
Hide thumbs Also See for TimeProvider 5000:
Table of Contents

Advertisement

Figure 4-33. Set SyncE Command Hierarchy
QL State for SyncE Outputs
1. Login at the Admin or Config-user level.
2. Type
set synce ql-state exp0 all enable
QL Mode for SyncE Outputs
1. Login at the Admin or Config-user level.
2. Type
set synce output-ql-mode exp0 port 1 bidirectional
Enter
ESMC for SyncE Outputs
1. Login at the Admin or Config-user level.
2. Type
set synce esmc exp0 port 1 enable

Setting the System Date and Time

The TimeProvider 5000 Time of Day can be set either by an external source, or
manually with the "set clock" command. You can set the time and date only in the
frequency reference mode (or SYS tod-source mode), but if the reference mode has
been set to time (default) or if TOD source has been set to GPS (default)], it is not
possible to set the time manually.
Note:
but can still be used as an alternate approach.
098-00028-000 Revision F – May, 2012
The
set tod-source
Setting the System Date and Time
and press Enter
and press Enter
command has been deprecated ,
TimeProvider 5000 User's Guide 345
Chapter 4 Provisioning
and press