set packet-service
Use the
set packet-service
PTP grandmaster, an NTP server, or a PTP probe. A license is required for a packet
service other than PTP grandmaster. The packet-service mode for IOC ports can be
set independently, with one port operating in PTP grandmaster mode while the
other port is configured for ptp-probe mode (IP addresses must be set to different
subnets).
Command Syntax:
set packet-service ioc1-x {ptp-gm | ntp-server | ptp-probe |
ntp-probe}
Note:
license.
NTP-probe is shown as a packet -service choice, however, it is an
internal feature reserved for Symmetricom use.
Example 1:
To configure port 2 of the IOC card as a PTP grandmaster:
set packet-service ioc1-2 ptp-gm
Example 2:
To configure port 1 of the IOC card as an NTP server:
set packet-service ioc1-1 ntp-server
Example 3:
To configure port 2 of the IOC card as a PTP probe:
set packet-service ioc1-1 ptp-probe
Note:
set ptp-probe-mode {enable|disable}
Level :
Admin only
098-00028-000 Revision F – May, 2012
command to configure the specified port as either a
PTP-probe and NTP-server each require a separate
The
set packet-service
TimeProvider 5000 CLI Command Set
command deprecates the
command.