Diagnostics; Led Signaling; Figure 47: Display Elements; Table 52: Led Assignment For Diagnostics - WAGO 750-370 Manual

Profinet io fieldbus coupler 2-port; 100 mbit/s; digital and analog signals
Hide thumbs Also See for 750-370:
Table of Contents

Advertisement

116

Diagnostics

Pos : 72 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Diag nos e/Di agnos e - Ü bersc hrift 1 @ 4\mod_1240831069471_21.doc x @ 31372 @ 1 @ 1
10
Diagnostics
Pos : 73 /Serie 750 ( WAGO-I/O-SYST EM)/Di agnose/Fel dbus koppl er/-contr oller/PROF INET-Di agnose/Diagnos emöglic hkei ten PROF INET - Ei nleitung @ 15\mod_1366792603400_21.doc x @ 117850 @ @ 1
In addition to diagnostics via the WBM (see previous section "Web-based
Management"), there are two other options for diagnostics for the fieldbus
coupler.
The listed diagnostic options are described below:

LED signaling

for onsite diagnostics
(see section "LED Signaling")
PROFINET IO diagnostics
by reading the diagnostic data sets (records)
(see section "PROFINET IO Diagnostics")
Pos : 74 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Diag nos e/LED-Signalisierung - Ü bers chrift 2 @ 4\mod_1240831118032_21.doc x @ 31375 @ 2 @ 1
10.1
LED Signaling
Pos : 75.1 /Serie 750 (WAGO-I/O-SYST EM)/Di agnose/Fel dbus koppl er/-contr oller/LED- Signalisierung - Einlei tung (Koppl er) @ 6\mod_1259564984171_21.doc x @ 46050 @ @ 1
For on-site diagnostics, the fieldbus coupler has several LEDs that indicate the
operational status of the fieldbus coupler or the entire node (see following figure).
Pos : 75.2 /Serie 750 (WAGO-I/O-SYST EM)/Ger ätebesc hrei bung/Anz eigeelemente/Fel dbus koppl er/-contr oller/Bilder/Anz eigeelemente 750- 0370 - Bild @ 22\mod_1429522520396_21.doc x @ 180576 @ @ 1

Figure 47: Display Elements

Pos : 75.3 /Serie 750 (WAGO-I/O-SYST EM)/Di agnose/Fel dbus koppl er/-contr oller/LED- Signalisierung - T abellenkopf, LED-Zuordnung für die Di agnos e (all e Koppl er/C ontroller) @ 6\mod_1256652265984_21.doc x @ 43750 @ @ 1
The diagnostics displays and their significance are explained in detail in the
following section.
The LEDs are assigned in groups to the various diagnostics areas:

Table 52: LED Assignment for Diagnostics

Diagnostics area
Pos : 75.4 /Serie 750 (WAGO-I/O-SYST EM)/Di agnose/Fel dbus koppl er/-contr oller/LED- Signalisierung - T abelle Fel dbuss tatus (LN K ACT 1, 2, BF , DIA) @ 23\mod_1435656647152_21.doc x @ 184896 @ @ 1
Pos : 75.5 /Serie 750 (WAGO-I/O-SYST EM)/Di agnose/Fel dbus koppl er/-contr oller/LED- Signalisierung - T abelle Knotens tatus (Koppler) I/O @ 4\mod_1240925540998_21.doc x @ 31853 @ @ 1
Pos : 75.6 /Serie 750 (WAGO-I/O-SYST EM)/Di agnose/Fel dbus koppl er/-contr oller/LED- Signalisierung - T abelle Versorgungss pannungsstatus A, B @ 6\mod_1256652844437_21.doc x @ 43753 @ @ 1
Status Supply Voltage
Pos : 75.7 /Dokumentation allgemei n/Glieder ungs elemente/---Seitenwechs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1
Fieldbus status
Node status
750-370 PROFINET IO Fieldbus Coupler
LEDs
• LNK ACT 1
• LNK ACT 2
• BF
• DIA
• I/O
• A (system supply)
• B (field supply)
WAGO-I/O-System 750