18.
Strauchen J, Alston W, Anderson J, Gustafson Z, Fajardo L: Inaccuracy in automated measure-
ment of hematocrit and corpuscular indices in the presence of severe hyperglycemia. Blood
57:1065-1067, 1981.
19.
Morse EE, Kalache G, Germino W, Stockwell R: Increased electronic mean corpuscular volume
induced by marked hyperglycemia. Annals Clin Lab Science 11:184-187, 1981.
20.
Holt JT, DeWandler MJ, Arvan DA: Spurious elevation of the electronically determined mean cor-
puscular volume and hematocrit caused by hyperglycemia. Am J Clin Pathol 77:561-567; 1982.
21.
Beautyman W, Bills T: Osmotic error in erythrocyte volume determinations. Am J Hemat 12:383-
389, 1982.
22.
Beautyman W, Bills T: Curious belief (letter to the editor). Am J Clin Pathol 79:143, 1983.
23.
Evan-Wong L, Davidson RJ: Raised coulter mean corpuscular volume in diabetic ketoacidosis,
and its underlying association with marked plasma hyperosmolarity. J Clin Pathol 36:334-336,
1983.
24.
Beautyman W, Bills T: More on MCV's and hyper- and hyponatremia. Am J Clin Pathol
80:548,1983.
25.
Savage RA, Hoffman GC: Clinical significance of osmotic matrix errors in automated hematology:
The frequency of hyperglycemic osmotic matrix errors producing spurious macrocytosis. Am J
Clin Pathol 80:861-865, 1983.
26.
Planas AT, Van Voolen GA, Kelly LA: Hyperglycemic macrocytosis n electronically determined
mean corpuscular volume: Use of three different automatic cell counters. Annals Clin Lab Science
15:286-291, 1985.
27.
Bock HA, Fluckiger R, Berger G: Real and artefactual erythrocyte swelling in hyperglycemia. Dia-
betologia 28:335-338, 1985.
Cold Agglutinin Interference on Automated Hematology Analyzers
28.
Brittin GM, Brecher G, Jonsom CA, et al: Spurious macrocytosis of antibody-coated red cells.
Amer J Clin Pathol 52:237-241, 1969.
29.
Hattersley PG, Gerard PW, Caggiano V, Nash DR: Erroneous values on the Model S Coulter
Counter due to high titer cold autoagglutinins. Am J Clin Pathol 55:442-446, 1971.
30.
Petrucci JV, Duanne PA, Chapman CC: Spurious erythrocyte indices as measured by the Model S
Coulter Counter due to cold agglutinins. Am J Clin Pathol 56:500-502, 1971.
31.
Bessman JD, Banks D: Spurious macrocytosis, a common clue to erythrocyte cold agglutinins.
Am J Clin Pathol 74:797-800, 1980.
32.
Solang SL, Blackburn BC: Spurious red blood cell parameters due to serum cold agglutinins: Ob-
servations on Ortho ELT-8 Cell Counter. Am J Clin Pathol 83:218-222, 1985.
Protein Interference on Conductivity Methods
33.
Bugarsky S, Tangl F: Physikalisch-chemisch untersuchungen uber die molecularen concentra-
tionsveraltnisse des blutserums. Arch Ges Physiol 72:53, 1898.
34.
Gram HC, Cullen GE: The accuracy of the 'ionometric' method and the protein correction in mea-
suring serum conductivity. J Biol Chem 57:447-491, 1923.
35.
Sunderman FW: Studies in serum electrolytes: XIII: Estimation of total base serum. J Biol Chem
143: 185-190, 1942.
36.
Kernan J, Wurzel H, Okada R: New electronic method for measuring hematocrit: Clinical evalua-
tion. J Lab Clin Med 57: 635-641, 1961.