FC 300 Design Guide
14-52
Fan Control
Value:
Auto
On 50%
On 75%
On 100%
Function:
Select minimum speed of internal fan.
Select Auto [0] to run fan only when internal tem-
perature in frequency converter is in range 35° C
to approx. 55° C.
Fan runs at low speed below 35° C, and at full
speed at approx. 55° C.
14-53
Fan Motor
Value:
Disabled
Warning
Trip
Function:
Select which reaction the frequency converter
should take in case a fan fault is detected.
14-55
Output Filter
Value:
No filter
Sine-Wave Filter
Function:
Select the type of output filter connected. This pa-
rameter cannot be adjusted while motor is run-
ning.
factory setting
222
How to Programme
[0]
[1]
[2]
[3]
[0]
[1]
[2]
[0]
[1]
()
display text
[]
value for use in communication via serial communication port
MG.33.B7.02 - VLT is a registered Danfoss trademark