NEC Express5800/120Rd-2 Service Manual page 217

Table of Contents

Advertisement

Fail to access the hard disk:
(Refer to the documentation supplied with the disk array controller.)
θ Is the hard disk applicable to the server?
θ Is the hard disk properly installed?
→ Make sure to lock the hard disk with the lever on its handle. The hard disk is not
connected to the internal connector when it is not completely installed (see
Chapter 7).
Fail to access the (internal or external) SCSI devices:
θ Is the SCSI device applicable to the server?
θ Are SCSI devices properly configured?
→ When the server has external SCSI devices connected, hard disk settings,
including SCSI ID and terminator, are required. Refer to the manual that comes
with the SCSI device for details.
θ Are the SCSI controllers (including optional controllers) properly configured?
→ Use the BIOS setup utility for proper configuration of SCSI devices connected to
the SCSI connector on the system board. When the server has an optional SCSI
controller installed and SCSI devices connected to it, use the BIOS setup utility
that comes with the optional SCSI controller for proper configuration. See the
manual that comes with the optional SCSI controller for details.
Cannot install the operating system correctly.
θ Did you read the notes on installing the operating system?
→ See Chapter 4. You should always use EXPRESSBUILDER when installing an
operating system on this server.
During Windows 2000 installation, the following warning is registered in the System Log of the Event Viewer:
Error detected on the device \Device\CdRom0 during the paging
operation.
→ There is no problem when this message occurs.
Troubleshooting 6-15

Advertisement

Table of Contents
loading